Fire doors basic guidance checklist introduction fire doors and all passive fire protection products play a unique role in fire.
Fire door inspection checklist pdf.
The assembly is composed of the fire door frame fire exit hardware door closers hinges locks door bolts and other door components that when combined provide varying degrees of fire protection that is contingent on the door fire rating e g.
We are certified to perform detailed 13 points fire doors inspection.
Fire door assembly inspection checklist the 2007 and 2010 editions of nfpa 80 standard for fire do ors and other opening protectives section 5 2 inspections require all fire doors to be inspect ed not less than annually.
Open the door about halfway let go and see.
Inspection and testing form nfpa inspection and testing 1 of 4 alarm notification appliances and circuit information quantity êêêêcircuit style bells horns chimes strobes speakers other specify.
View the vision panel and glass from both sides of the door.
Manual fire alarm boxes ion detectors photo detectors duct detectors heat detectors waterflow switches supervisory switches other specify.
This detailed fire door inspection checklist can be used to survey the overall condition of fire doors.
For best results use a checkmate fire gap gauge or use a 1 coin to give a feel for scale this is about 3mm thick.
The 2012 edition of the life safety code nfpa 101 requires facilities to complete annual fire and smoke door inspection and testing.
Open the door and take a look at the hinges.
In addition to all of the components of a fire door assembly.
Fire door safety week 2018 which runs from september 24th to 30th is designed to promote awareness of the importance of choosing the right fire doors and ensuring they are properly installed and maintained.
To help you implement the advice you are given during the week checkmate fire has compiled a downloadable fire door inspection checklist.
Fire hydrants should be visible and accessible.
Means of egress all exit doors should be visible accessible and fully functional.
All exit doors should readily open from the inside without the use of a key or special knowledge or effort.
45 minutes 90 minutes.
All required fire doors must be self closing and latch in the closed position.
Section 18 2 2 2 1 19 2 2 2 1 requires compliance with section 7 2 1 and section 7 2 1 15 2 requires compliance with nfpa 80 standard.
The frequency of each inspection should be determined by assessing among other things the amount of use the door is subjected to the criticality of the.
Fire doors are fire resistant equipment that need to be checked regularly to make sure they still offer protection to other parts of the building.